Related Experiment Video
Updated: Jan 18, 2026

Coherent anti-Stokes Raman Scattering CARS Microscopy Visualizes Pharmaceutical Tablets During Dissolution
Published on: July 4, 2014
Quantification of a cocrystal and its dissociated compounds in solid dosage form using transmission Raman
Tatsuo Koide1, Yuki Takeuchi2, Takashi Otaki3
1Division of Drugs, National Institute of Health Sciences, Tonomachi, Kawasaki-ku, Kawasaki, 210-9501, Japan.
Abstract:
The performance of transmission Raman spectroscopy (TRS) for quantifying a cocrystal and its dissociation in solid dosage form was investigated. Some tablets containing 0%-20% (w/w) of a cocrystal of carbamazepine (CBZ)/succinic acid (SUC), 0%-4% of CBZ, 0%-4% of SUC, and 75%-99% of D-mannitol were prepared. The Raman spectra of these tablets were preprocessed using the standard normal variate (SNV) or multiplicative scatter correction (MSC) as well as the Savitzky Golay second derivative, and then, these were used to generate calibration models using partial least squares (PLS) regression. The performance of the model was superior when the MSC preprocessing spectra of the cocrystal between 200 and 1800 cm-1 were used for calibration. The determination coefficient of the PLS calibration curve for the CBZ/SUC cocrystal between 200 and 1800 cm-1 with MSC was 0.97, root mean square error of cross validation (RMSECV) was 1.16, and root mean square error of prediction (RMSEP) was 1.10. As in the case of the CBZ/SUC cocrystal, the performance of the model was superior when the MSC preprocessing spectra of CBZ and SUC between 200 and 1800 cm-1 were used for calibration. These data suggest that TRS is useful for quantifying a cocrystal and its dissociation compounds in solid dosage forms.
More Related Videos
06:54Characterization of Nanocrystal Size Distribution using Raman Spectroscopy with a Multi-particle Phonon Confinement Model
Published on: August 22, 2015
11:07Visualizing and Quantifying Pharmaceutical Compounds within Skin using Coherent Raman Scattering Imaging
Published on: November 24, 2021
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Recrystallization: Solid–Solution Equilibria
Drug Dissolution: Requirements and Profile Comparison