Related Experiment Video
Updated: Jan 18, 2026

Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
Operating Cost and Treatment of Boron from Aqueous Solutions by Electrocoagulation in Low Concentration
1Department of Environmental Engineering Engineering Faculty Mersin University 33343 Mersin Turkey.
Abstract:
The objective of this study is to determine the optimum parameters of electrocoagulation process in treatment of boron in low concentrations. Especially, studies on electrode optimization in low boron concentrated waters are insufficient. Therefore, the effect of electrode combination (Al-Al, Al-Fe, Al-SS, Fe-Al, Fe-Fe, and Fe-SS), pH (5-9), current density (8-24 mA cm-2), distance (1-3 cm), and electrolysis time (10-90 min) on treatment of boron containing wastewater is studied to obtain maximum removal efficiency. The maximum removal efficiency of boron is obtained as 95.6%. Operation conditions for maximum removal are the electrode combination of Fe-Al, current density of 16 mA cm-2, pH 7.0, concentration of 30 mg L-1 and the reaction time of 70 min. Operating cost of the electrocoagulation process is calculated as 2.35 $ m-3. This study indicates that the electrocoagulation process can be successfully applied in order to treat boron-polluted wastewaters at low initial concentrations.
Related Concept Videos
Coagulation
Electrolysis
Electrodeposition
Electrodeposition can...
Hydroboration-Oxidation of Alkenes
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Colloidal precipitates