Related Experiment Video
Updated: Jan 18, 2026

Ex Situ Normothermic Machine Perfusion of Donor Livers
Published on: May 26, 2015
Renal Protection Against Ischemia Reperfusion Injury: Hemoglobin-based Oxygen Carrier-201 Versus Blood as an Oxygen
Rabindra N Bhattacharjee1,2,3, Sanjay V B Patel4, Qizhi Sun2,3
1Department of Surgery, Western University, London, ON, Canada.
Background:
The optimal method of oxygen delivery to donor kidneys during ex vivo machine perfusion has not been established. We have recently reported the beneficial effects of subnormothermic (22°C) blood perfusion in the preservation of porcine donation after circulatory death kidneys. Since using blood as a clinical perfusate has limitations, including matching availability and potential presence of pathogen, we sought to assess hemoglobin-based oxygen carrier (HBOC-201) in oxygen delivery to the kidney for renal protection.
Methods:
Pig kidneys (n = 5) were procured after 30 minutes of warm in situ ischemia by cross-clamping the renal arteries. Organs were flushed with histidine tryptophan ketoglutarate solution and subjected to static cold storage or pulsatile perfusion with an RM3 pump at 22°C for 4 hours with HBOC-201 and blood. Thereafter, kidneys were reperfused with normothermic (37°C) oxygenated blood for 4 hours. Blood and urine were subjected to biochemical analysis. Total urine output, urinary protein, albumin/creatinine ratio, flow rate, resistance were measured. Acute tubular necrosis, apoptosis, urinary kidney damage markers, neutrophil gelatinase-associated lipocalin 1, and interleukin 6 were also assessed.
Results:
HBOC-201 achieved tissues oxygen saturation equivalent to blood. Furthermore, upon reperfusion, HBOC-201 treated kidneys had similar renal blood flow and function compared with blood-treated kidneys. Histologically, HBOC-201 and blood-perfused kidneys had vastly reduced acute tubular necrosis scores and degrees of terminal deoxynucleotidyl transferase 2'-deoxyuridine, 5'-triphosphate nick end labeling staining versus kidneys treated with cold storage. Urinary damage markers and IL6 levels were similarly reduced by both blood and HBOC-201.
Conclusions:
HBOC-201 is an excellent alternative to blood as an oxygen-carrying molecule in an ex vivo subnormothermic machine perfusion platform in kidneys.