Related Experiment Video
Updated: Jan 6, 2026
![PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F57243.jpg&w=3840&q=50)
12:01
PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke
Published on: June 14, 2018
13.2K
Different preprocessing strategies lead to different conclusions: A [11C]DASB-PET reproducibility study.
Martin Nørgaard1,2, Melanie Ganz1,3, Claus Svarer1
1Neurobiology Research Unit, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Summary
Positron emission tomography (PET) neuroimaging preprocessing significantly impacts study outcomes. Motion correction is crucial for reliable results in [11C]DASB-PET studies investigating serotonin transporter binding and depression.
Area of Science:
- Neuroimaging
- Pharmacology
- Psychiatry
Background:
- Positron emission tomography (PET) enables in vivo study of biological processes.
- PET data quantification relies on preprocessing pipelines, but their impact on outcomes is often unclear.
- The choice of data analysis methods can influence research findings.
Purpose of the Study:
- To evaluate the impact of 384 preprocessing strategies on [11C]DASB-PET data.
- To assess how preprocessing affects the association between serotonin transporter binding and depressive symptoms after hormone manipulation.
- To identify critical preprocessing steps influencing study outcomes.
Main Methods:
- Utilized a dataset from a double-blind, randomized, placebo-controlled [11C]DASB-PET study in 30 women.
- Applied 384 distinct preprocessing pipelines to dynamic PET data.
- Analyzed the influence of motion correction and kinetic modeling on reported findings.
Main Results:
- Only 36% of all tested preprocessing strategies replicated the original positive finding (p < 0.05).
- Preprocessing strategies incorporating motion correction achieved a 72% replication rate.
- Strategies lacking motion correction failed to replicate the finding (0% replication).
Conclusions:
- The selection of preprocessing strategies critically influences the outcomes of [11C]DASB-PET studies.
- Motion correction is a vital component for reproducible results in this neuroimaging modality.
- Standardizing preprocessing pipelines is essential for reliable interpretation of PET neuroimaging data.
Related Concept Videos
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.6K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.6K
Positron Emission Tomography
6.8K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
6.8K