Related Experiment Video
Updated: Jan 6, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Aerosol Delivery During Continuous High Frequency Oscillation for Simulated Adults During Quiet and Distressed
Jie Li1, Ahmad A Elshafei2, Lingyue Gong2
1Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, Illinois. jie_li@rush.edu.
Background:
Continuous high-frequency oscillation (CHFO) is a therapeutic mode for the mobilization of secretions. The Metaneb CHFO device also incorporates aerosol administration using an integrated jet nebulizer. However, the effectiveness of aerosol delivery and influential factors remain largely unreported.
Methods:
A collecting filter was placed between an adult manikin with a representative upper airway and a breath simulator, set to simulate quiet and distressed patterns of spontaneous adult breathing. The Metaneb CHFO device was attached to the manikin via a mask. Two jet nebulizers were tested in 2 different positions: placement in the manifold and placement between manifold and mask. A vibrating mesh nebulizer was placed between the manifold and mask with and without extension tubing. Aerosol administration was compared during CHFO and during nebulization mode alone. Albuterol (2.5 mg in 3 mL) was nebulized for each condition. The drug was eluted from the filter and assayed with ultraviolet spectrophotometry (276 nm).
Results:
During CHFO, inhaled doses with jet nebulizers were low (∼ 2%), regardless of nebulizer placement. Inhaled dose was improved with the vibrating mesh nebulizer placed between the manifold and mask (12.48 ± 2.24% vs 2.58 ± 0.48%, P = .004). Inhaled doses with the jet nebulizer in the manifold with nebulization mode alone was lower than with the jet nebulizer with an aerosol mask (4.03 ± 1.82% vs 10.39 ± 2.79%, P = .004). Inhaled dose was greater with distressed breathing than quiet breathing. The use of a vibrating mesh nebulizer (P < .001) and distressed breathing (P = .001) were identified as predictors of increased inhaled dose.
Conclusions:
Inhaled dose with a jet nebulizer via the Metaneb CHFO device was lower than with a jet nebulizer alone. Placement of a vibrating mesh nebulizer at the airway and distressed breathing increased inhaled dose.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Cardiopulmonary Resuscitation II: ACLS Airway Management