Cardiac output measurements via echocardiography versus thermodilution: A systematic review and meta-analysis
Yun Zhang1, Yan Wang2, Jing Shi1
1Department of Emergency Medicine, Wuxi People's Hospital Affiliated to Nanjing Medical University, Wuxi, Jiangsu, China.
Abstract:
Echocardiography, as a noninvasive hemodynamic evaluation technique, is frequently used in critically ill patients. Different opinions exist regarding whether it can be interchanged with traditional invasive means, such as the pulmonary artery catheter thermodilution (TD) technique. This systematic review aimed to analyze the consistency and interchangeability of cardiac output measurements by ultrasound (US) and TD. Five electronic databases were searched for studies including clinical trials conducted up to June 2019 in which patients' cardiac output was measured by ultrasound techniques (echocardiography) and TD. The methodological quality of the included studies was evaluated by two independent reviewers who used the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2), which was tailored according to our systematic review in Review Manager 5.3. A total of 68 studies with 1996 patients were identified as eligible. Meta-analysis and subgroup analysis were used to compare the cardiac output (CO) measured using the different types of echocardiography and different sites of Doppler use with TD. No significant differences were found between US and TD (random effects model: mean difference [MD], -0.14; 95% confidence interval, -0.30 to 0.02; P = 0.08). No significant differences were observed in the subgroup analyses using different types of echocardiography and different sites except for ascending aorta (AA) (random effects model: mean difference [MD], -0.37; 95% confidence interval, -0.74 to -0.01; P = 0.05) of Doppler use. The median of bias and limits of agreement were -0.12 and ±0.94 L/min, respectively; the median of correlation coefficient was 0.827 (range, 0.140-0.998). Although the difference in CO between echocardiography by different types or sites and TD was not entirely consistent, the overall effect of meta-analysis showed that no significant differences were observed between US and TD. The techniques may be interchangeable under certain conditions.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...