Related Experiment Video
Updated: Jan 6, 2026

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Quantitative Analysis of Organic Liquid Three-Component Systems: Near-Infrared Transmission versus Raman
Hui Yan1, Yue Ma2, Zhixin Xiong3
1School of Biotechnology, Jiangsu University of Science and Technology, Zhenjiang 212018, China. yanh1006@163.com.
Abstract:
The band shapes and band positions of near-infrared (NIR) and Raman spectra change depending on the concentrations of specific chemical functionalities in a multicomponent system. To elucidate these effects in more detail and clarify their impact on the analytical measurement techniques and evaluation procedures, NIR transmission spectra and Raman spectra of two organic liquid three-component systems with variable compositions were analyzed by two different multivariate calibration procedures, partial least squares (PLS) and classical least-squares (CLS) regression. Furthermore, the effect of applying different concentration units (volume percent (%V) and weight percent (%W) on the performance of the two calibration procedures have been tested. While the mixtures of benzene/cyclohexane/ethylbenzene (system 1) can be regarded as a blended system with comparatively low molecular interactions, hydrogen bonding plays a dominant role in the blends of ethyl acetate/1-heptanol/1,4-dioxane (system 2). Whereas system 1 yielded equally good calibrations by PLS and CLS regression, for system 2 acceptable results were only obtained by PLS regression. Additionally, for both sample systems, Raman spectra generally led to lower calibration performance than NIR spectra. Finally, volume and weight percent concentration units yielded comparable results for both chemometric evaluation procedures.
More Related Videos
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

