Related Experiment Video
Updated: Jan 6, 2026

Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
Reported Severe Hypersensitivity Reactions after Intravenous Iron Administration in the European Economic Area (EEA)
Lennart Nathell1, Annegret Gohlke2, Stefan Wohlfeil3
1Nathell Medical AB, Växthusvägen 6, 582 76, Linköping, Sweden.
Introduction:
Severe hypersensitivity reactions (HSRs) such as anaphylaxis are of great clinical concern because of their life-threatening potential. The adverse events attributable to intravenous iron products include HSRs. An investigation by the European Medicines Agency presented in late 2013 resulted in the implementation of risk minimization measures (RMMs).
Objective:
This study evaluated the number of severe HSRs reported for intravenous iron substances related to exposure for the 4-year periods before and after this implementation.
Methods:
This was a retrospective pharmacoepidemiologic study with a case-population design. We obtained information from the safety surveillance database EudraVigilance on spontaneously reported severe HSRs using the Medical Dictionary for Regulatory Activities preferred terms "anaphylactic reaction/shock" and "anaphylactoid reaction/shock". Exposure was estimated using IQVIA MIDAS sales data in European economic area countries.
Results:
Reporting rates for individual products were heterogenous, and the implementation of RMMs appeared to have no clear impact. Reporting rates remained low for the full study period for iron sucrose (0.03-0.20) and ferric gluconate (0.02-0.14) and were higher at the beginning and lower at the end of the study period for ferric carboxymaltose (1.47-0.18). No clear trend was detected for iron dextran (range 0.22-2.80) and iron (III) isomaltoside 1000 (range 0-7.94).
Conclusions:
Future research is needed to investigate whether the wide variability in reporting rates for severe HSRs associated with these intravenous iron products are due to potential differences in the safety profiles of these substances.
More Related Videos
04:40Dynamic Light Scattering Analysis for the Determination of the Particle Size of Iron-Carbohydrate Complexes
Published on: July 7, 2023
06:31Precision Implementation of Minimal Erythema Dose MED Testing to Assess Individual Variation in Human Inflammatory Response
Published on: October 3, 2019
Related Concept Videos
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Allergic Drug Reactions
Hypersensitivities
Types of Hypersensitivities
Hypersensitivity reactions are categorized into four types: Type 1, Type 2, Type 3, and Type 4. Each type has a distinct mechanism...
Allergic Reactions
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Effect of Hepatic Disease on Pharmacokinetics: Dose Adjustments Due to Hepatic Impairment