Related Experiment Video
Updated: Jan 6, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
An analytical fit and EGSnrc code (MC) calculations of personal dose equivalent conversion coefficients for
Hassan Al Kanti1, O El Hajjaji1, T El Bardouni1
1Radiations and Nuclear Systems Laboratory, Abdelmalek Essaadi University, Faculty of Sciences, Tetouan, Morocco.
Abstract:
This study aims for calculating a new set of the personal dose equivalent conversion coefficients Hp(d)/Φ when d = 0.07, 3, and 10 mm, for mono-energetic electron beams ranged from 0.06 MeV to 50 MeV for Hp(0.07), from 0.7 MeV to 50 MeV for Hp(3) and from 2 MeV to 50 MeV for Hp(10), which has incident on ICRU slab phantom. Additionally, we have calculated the conversion coefficients of a dose to the lens eye of into a new cylindrical phantom of the ORAMED project. The cylindrical phantom was proposed for calculating the eye lens dose equivalent as a cylinder much better approximates the form of a head than a slab. The ICRU tissue of density of 1 g/cm3 which is consists of 4-elemental has been used in slab and cylindrical phantoms. The calculations were carried out with EGSnrc code Monte Carlo (MC) and a new an analytical fit is applied to the data. Our results are found in a good agreement with those published by Veinot and Hertel (2012)) , with a local difference less than 1.5%. We have concluded that new analytical fits provide a convenient approach for determining conversion coefficients for discrete incident such as MC.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Atomic Emission Spectroscopy: Overview
Dose Size and Dosing Frequency: Determination Methods
Atomic Emission Spectroscopy: Lab
Mechanistic Models: Compartment Models in Individual and Population Analysis
Radioactivity and Nuclear Equations
A nuclide of an element has a specific number of protons and...