Related Experiment Video
Updated: Jan 6, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Positive molecular breast imaging: challenges and problem solving with contrast-enhanced spectral mammography
Jeremy Sl Ong1,2, Felicity Whitewood3, Donna B Taylor4
1Medical Imaging, Fiona Stanley Hospital, Murdoch, Western Australia, Australia.
Abstract:
Molecular breast imaging (MBI) is a relatively new technique with high sensitivity for breast cancer detection. However, because it only provides limited anatomical information, cross-correlation of MBI findings with conventional breast imaging modalities such as full field digital mammography can be challenging. We report a case of a positive MBI study in a supplemental screening setting, where cross-correlation of MBI, ultrasound, mammogram and biopsy findings was difficult. Contrast-enhanced spectral mammography (CESM) demonstrated a hypervascular lesion at the biopsy clip, helping to prove imaging/histopathological concordance. This case highlights the challenges of incorporating MBI into conventional imaging workup, as well as the use of CESM in problem solving.