Endotracheal suctioning for prevention of meconium aspiration syndrome: a randomized controlled trial

Ashok Kumar1, Preetam Kumar2, Sriparna Basu3

  • 1Neonatal Unit, Department of Pediatrics, Institute of Medical Sciences, Banaras Hindu University, Varanasi, 221005, India. ashokkumar_bhu@hotmail.com.

The current version of Neonatal Resuscitation Program no longer favors routine endotracheal suctioning (ETS) in non-vigorous newborns with meconium-stained amniotic fluid (MSAF) due to possibility of procedure-related harms and questionable benefits. However, it calls for additional research on this procedure to provide a definitive answer. The present study was conducted to evaluate the role of ETS in non-vigorous neonates of ≥ 34 weeks' gestation born through MSAF on the incidence of meconium aspiration syndrome (MAS). In this open-label randomized controlled trial, 132 non-vigorous neonates with MSAF were randomized to receive ETS (n = 66) or no-ETS (n = 66) during delivery room resuscitation (DRR). Primary outcome variable was incidence of MAS. Secondary outcome variables were requirement of DRR, need of respiratory support, development of complications, duration of hospitalization, and mortality. Both the groups were comparable with respect to maternal and neonatal characteristics. Incidence of MAS was 21 (31.8%) and 15 (22.7%) cases in ETS and no-ETS groups, respectively (relative risk (RR), 1.400, 95% confidence interval (CI), 0.793-2.470). The two groups did not differ with regard to DRR, need for respiratory support, and development of complications. Nine (13.6%) neonates in ETS group, and 5 (7.5%) in no-ETS group died (p > 0.05). Median (interquartile range) duration of hospital stay was 54 (31-141) h and 44 (26-102) h in ETS and no-ETS groups, respectively (p > 0.05).Conclusions: Routine ETS at birth is not useful in preventing MAS in non-vigorous neonates of ≥ 34 weeks' gestation born through MSAF.Trial registration: Clinical Trials Registry of India (CTRI/2015/04/008819).What is Known:• Routine endotracheal suctioning is of questionable benefit in non-vigorous newborns with meconium stained amniotic fluid and may have a possibility of procedure-related harms.What is New:• Routine endotracheal suctioning at birth is not useful in preventing meconium aspiration syndrome in non-vigorous newborns of ≥ 34 weeks' gestation born through meconium stained amniotic fluid.

Related Concept Videos

Suctioning the Nasopharyngeal Airway01:29

Suctioning the Nasopharyngeal Airway

Nasopharyngeal suctioning is a procedure to remove secretions from the upper part of the respiratory tract that the patient cannot clear independently. It helps maintain airway patency and prevents complications such as aspiration pneumonia.
Equipment Required
2.7K
Tracheostomy Suctioning II: Procedure01:23

Tracheostomy Suctioning II: Procedure

Tracheostomy suctioning is a vital nursing procedure that involves removing secretions from the tracheostomy tube to maintain airway patency and prevent respiratory complications. Nurses need to understand the proper technique for tracheostomy suctioning to ensure patient safety and comfort. In this guide, we will outline the step-by-step process for performing tracheostomy suctioning, including preparing the sterile field, donning personal protective equipment (PPE), lubricating and connecting...
1.4K
Tracheostomy Suctioning I: Pre-Procedural Steps01:26

Tracheostomy Suctioning I: Pre-Procedural Steps

Tracheostomy suctioning is a critical procedure healthcare professionals perform to maintain a patent airway in patients with a tracheostomy tube. This procedure is necessary when secretions accumulate in the airway, causing respiratory distress. Here is a step-wise procedural guide for performing tracheostomy suctioning using an open system.
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
1.9K
Suctioning the Oropharyngeal Airway01:25

Suctioning the Oropharyngeal Airway

In preparing for oropharyngeal airway suctioning, a nurse must gather all necessary equipment, including a suction unit with tubing, a prepackaged suction kit, sterile gloves, water or saline for irrigation, a water-soluble lubricant, and additional personal protective equipment (such as a gown, mask, and goggles) to control infections.
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
728
Endoscopic Studies II: Thoracocentesis01:26

Endoscopic Studies II: Thoracocentesis

Thoracentesis(Thoracocentesis), commonly known as pleural tap, is a medical procedure where a 22 gauge needle is inserted into the pleural space, the area between the lung and chest wall. This procedure is commonly performed to diagnose or treat various respiratory disorders.
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
1.2K
Endotracheal Intubation I: Procedure01:15

Endotracheal Intubation I: Procedure

Endotracheal or ET intubation is a critical medical procedure used to secure a patient's airway, often in acute respiratory distress, apnea, upper airway obstruction, ineffective clearance of secretions, high risk for aspiration, or during general anesthesia.
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
7.0K