Isovelocity vs. Isoinertial Sprint Cycling Tests for Power- and Torque-cadence Relationships
Mehdi Kordi1,2, Jonathan Folland3, Stuart Goodall1
1Department of Sport Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom of Great Britain and Northern Ireland.
Abstract:
Sprint cycling performance is heavily dependent on mechanical peak power output (PPO) and the underlying power- and torque-cadence relationships. Other key indices of these relationships include maximum torque (TMAX), cadence (CMAX) and optimal cadence (COPT). Two common methods are used in the laboratory to ascertain PPO: isovelocity and isoinertial. Little research has been carried out to compare the magnitude and reliability of these performance measures with these two common sprint cycling assessments. The aim of this study was to compare the magnitude and reliability of PPO, TMAX, CMAX and COPT measured with isovelocity and isoinertial sprint cycling methods. Two experimental sessions required 20 trained cyclists to perform isoinertial sprints and then isovelocity sprints. For each method, power-cadence and torque-cadence relationships were established, and PPO and COPT were interpolated and TMAX and CMAX were extrapolated. The isoinertial method produced significantly higher PPO (p<0.001) and TMAX (p<0.001) than the isovelocity method. However, the isovelocity method produced significantly higher COPT (p<0.001) and CMAX (p=0.002). Both sprint cycling tests showed high levels of between-session reliability (isoinertial 2.9-4.4%; isovelocity 2.7-4.0%). Functional measures of isovelocity and isoinertial sprint cycling tests were highly reliable but should not be used interchangably.
Related Concept Videos
Net Torque Calculations
Work and Power for Rotational Motion
Similarly, the power delivered to a system that is rotating about a fixed axis...
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Torque
Torque can be considered as the rotational counterpart to force. Since forces change the translational...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Efficiency of The Carnot Cycle


