Validating gingival surface temperature as an alternative tool in the diagnosis of periodontal disease activity: An observational clinical trial
Related Experiment Video
Updated: Jan 6, 2026

A Novel Approach to Monitoring Graft Neovascularization in the Human Gingiva
Published on: January 12, 2019
Sumanth Gunupati1, Hasya Sappiti1, Sreenivas Nagarakanti1
1Department of Periodontology, Narayana Dental College & Hospital, Nellore, Andhra Pradesh, India.
Abstract:
Elevated temperature has been recognized as an inflammatory sign. It is the only indication that can be both objectively and quantitatively evaluated and is considered as a potential indicator of periodontal disease. Assessing gingival surface temperature (GST) could be a diagnostic parameter to determine periodontal health. This pilot clinical study aimed to validate gingival surface temperature (GST) as a clinical diagnostic tool to measure periodontal disease activity by correlating with the periodontal inflamed surface area (PISA). A cross-sectional mono-center pilot study was conducted with a convenient sample of 50 participants with a mean age of 34.14±13.7 years. Clinical parameters such as probing pocket depth (PPD) clinical attachment loss (CAL) and bleeding on probing (BOP) were measured. GST was recorded with a single lead of the bedside patient monitor and correlated with PISA. The results showed a positive correlation between PISA and GST (P=0.46). This study showed a rise in GST of inflamed sites, but the results did not support the hypothesis that increased GST is an indicator of periodontal disease. As this is a pilot study, further studies with more larger sample sizes need to be undertaken to confirm its use as a diagnostic tool in clinical trials.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...