Employing Digital Droplet PCR to Detect BRAF V600E Mutations in Formalin-fixed Paraffin-embedded Reference Standard Cell Lines
Published on: October 8, 2015
Interlaboratory assessment of droplet digital PCR for quantification of BRAF V600E mutation using a novel DNA
Lianhua Dong1, Xia Wang1, Shangjun Wang2
1Center for Advanced Measurement Science, National Institute of Metrology, Beijing, 100013, PR China.
Abstract:
Droplet digital PCR (ddPCR) has attracted much attention in the detection of genetic signatures of cancer present at low levels in circulating tumor DNA (ctDNA) in blood. A growing number of laboratory-developed liquid biopsy tests based on such technology have become commercially available for clinical settings. To obtain consistent and comparable results, an international standard is necessary for validation of the analytical performance. In this study, a novel and SI-traceable "ctDNA" reference material (RM) carrying BRAF V600E was prepared by gravimetrically mixing a 152 bp PCR amplicon and sonicated wild-type genomic DNA. The ddPCR performance was evaluated by analyzing serial "ctDNA" dilutions using a competitive MGB assay. The mutant frequency concordance (k) between ddPCR and the gravimetrical value was 1.03 in the range from 53.9% to 0.1%. The limit of blank (LoB), detection (LoD) and quantification (LoQ) of ddPCR assay were determined to be 0.01%, 0.02% and 0.1%, respectively. Results from the interlaboratory study, using challenging low levels of BRAF V600E ctDNA RMs, demonstrated that the participating laboratories had the appropriate technical competency to perform accurate ddPCR-based low level of ratio measurements. However, a systematic error caused by uncorrected droplet volume in Naica Crystal ddPCR platform was found by using the ctDNA RM. Between-laboratory consistency in copy number measurement was greatly improved when a correct droplet volume was applied for the ddPCR measurement by using the ctDNA RM. This confirms that the "ctDNA" RM is fit for the validation of ddPCR systems for ctDNA quantification. This would also support translation of tests for circulating tumor DNA by ddPCR into routine use.
More Related Videos
13:24Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
Published on: April 11, 2016
08:23Single Droplet Digital Polymerase Chain Reaction for Comprehensive and Simultaneous Detection of Mutations in Hotspot Regions
Published on: September 25, 2018