Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction
Abstract:
Effects of inaccurate attenuation correction on quantitation in positron emission computed tomography were investigated by both computer simulation and theoretical analysis, followed by experimental verification with phantom measurements. It was found that, due to the finite width of detector responses, compensation of scan measurements by measured attenuation correction factors does not completely correct for attenuation. For FWHM greater than 1.8 cm, errors in object size and in activity levels of reconstructed images are more than 4%. Mismatches between true and assumed attenuation media are found to give large errors. These mismatches include object shift, incorrect size and shape, uniform and nonuniform mismatches in attenuation coefficients, and nonzero background levels. Errors as large as 14% in the reconstructed activity level can be introduced by a 5 mm shift in object position. A 5% error in the cylinder diameter can give differences between the total reconstructed activity and true value more than 12%. Strong image distortions, which could lead to incorrect interpretations of images are created by object shift and by nonuniform mismatches in attenuation coefficient. It was also found that statistical noise in measured attenuation correction factors can significantly increase noise levels in images, resulting in lower effective total counts for the emission scan. Effective total counts can be estimated as Neff = kNxmNem/(Nem + kNxm), where Nem and Nxm are total counts in emission and transmission scans, and k is a scanner dependent factor, which accounts for configuration differences.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET