Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Improvement in Survival Rates and Quality of Life Among Patients Surgically Treated for Squamous Cell Carcinoma of the Oral Cavity.

Journal of maxillofacial and oral surgery·2026
Same author

Risk of Cervical Metastasis in Primary Parotid Gland Malignancies: A Yo-IFOS Multicenter Retrospective Longitudinal Study.

Head & neck·2026
Same author

Recurrences and Survival in Oropharyngeal Squamous Cell Carcinoma According to p16 Status and Extranodal Extension.

Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery·2026
Same author

CT-defined posterior extension predicts pathological nodal metastasis in lower oral cavity squamous cell carcinoma.

European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery·2026
Same author

Surgical management of T4a supraglottic carcinoma: considerations on the updated NCCN guidelines.

Oral oncology·2026
Same author

Reply to the commentary on "Impact of time-to-surgery on survival and quality of life in oral cancer".

American journal of otolaryngology·2026

Related Experiment Video

Updated: Jan 6, 2026

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
06:54

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery

Published on: August 4, 2023

1.7K

Cochlear Implant Surgery: How to Fix Receiver/Stimulator Avoiding Extrusion.

Annalisa Gatto1, Margherita Tofanelli1, Alice Piccinato1

  • 1Department of Otorhinolaryngology, Head and Neck Surgery, 9315University of Trieste, Cattinara Hospital, Trieste, Italy.

Ear, Nose, & Throat Journal
|October 11, 2019
PubMed
Summary

This pilot study introduces a novel technique for securing cochlear implant receiver/stimulators (R/S) using Mitek suture anchors. This method enhances R/S stability, potentially reducing complications and re-implantation needs.

Keywords:
cochlear implantfixation techniquehearing losspostoperative complicationsreceiver/stimulator extrusion

More Related Videos

Performing Intracochlear Electrocochleography During Cochlear Implantation
09:10

Performing Intracochlear Electrocochleography During Cochlear Implantation

Published on: March 8, 2022

4.9K
Robotic Cochlear Implantation for Direct Cochlear Access
08:06

Robotic Cochlear Implantation for Direct Cochlear Access

Published on: June 16, 2022

3.9K

Related Experiment Videos

Last Updated: Jan 6, 2026

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
06:54

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery

Published on: August 4, 2023

1.7K
Performing Intracochlear Electrocochleography During Cochlear Implantation
09:10

Performing Intracochlear Electrocochleography During Cochlear Implantation

Published on: March 8, 2022

4.9K
Robotic Cochlear Implantation for Direct Cochlear Access
08:06

Robotic Cochlear Implantation for Direct Cochlear Access

Published on: June 16, 2022

3.9K

Area of Science:

  • Otolaryngology
  • Neurosurgery
  • Biomedical Engineering

Background:

  • Cochlear implant (CI) surgery is generally safe but can lead to complications.
  • Receiver/stimulator (R/S) extrusion and electrode migration may necessitate revision surgery.
  • Current fixation methods may have limitations in ensuring long-term stability.

Purpose of the Study:

  • To describe and evaluate a new technique for firmly fixing the cochlear implant R/S.
  • To assess the efficacy of the Mitek suture anchors system for improving R/S stability.
  • To determine if this technique can reduce the incidence of CI-related complications.

Main Methods:

  • A pilot study was conducted to test a novel R/S fixation technique.
  • The Mitek suture anchors system was utilized to create a secure suture web.
  • Two different Mitek device models were evaluated for their performance in R/S fixation.

Main Results:

  • The suture web created by the Mitek system demonstrated improved stability of the R/S.
  • The R/S showed a more secure bond to the underlying curved bone surface.
  • The technique was found to be less laborious compared to conventional methods.

Conclusions:

  • The Mitek suture anchors system offers a promising new method for R/S fixation in CI surgery.
  • This technique can enhance the stability of the R/S, potentially lowering complication rates.
  • Further studies are warranted to confirm the long-term efficacy and safety of this approach.