Related Experiment Video
Updated: Jan 6, 2026

Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
Diagnostic values of the femoral pulse palpation test
Fatine Khammari Nystrom1, Gunnar Petersson1, Olof Stephansson1,2
1Department of Medicine Solna, Clinical Epidemiology Unit, Karolinska Institutet, Stockholm, Sweden.
Objectives:
To calculate diagnostic values of the femoral pulse palpation to detect coarctation of the aorta or other left-sided obstructive heart anomalies in newborn infants.
Design:
Population-based cohort study.
Setting:
Stockholm-Gotland County 2008-2012.
Patients:
All singleton live-born infants without chromosomal trisomies, at ≥35 gestational weeks, followed-up until 1-2 years of age.
Main Outcome Measures:
Diagnostic values and ORs for the femoral pulse test and subsequent diagnosis of coarctation of the aorta or left-sided obstructive heart malformation.
Results:
Among the 118 592 included infants, 432 had weak or absent femoral pulses at the newborn examination. Seventy-eight infants were diagnosed with coarcation of the aorta and 48 with other left-sided obstructive heart malformations. The diagnostic values for the femoral pulse palpation test to detect coarctation of the aorta were: sensitivity: 19.2%, specificity: 99.6, positive predictive value: 3.5% and negative predictive value: 99.9%. For left-sided heart malformations: sensitivity: 8.3%, specificity: 99.6%, positive predictive value: 0.9% and negative predictive value: 100%. Sensitivity for coarctation of the aorta increased from 16.7% when examined at <12 hours of age to 30.0% at ≥96 hours of age.
Conclusions:
The femoral pulse test to detect coarctation of the aorta and left-sided heart malformations has limited sensitivity, whereas specificity is high. As many infants with life-threatening cardiac malformations leave the maternity ward undiagnosed, further efforts are necessary to improve the diagnostic yield of the routine newborn examination.
Related Concept Videos
Pulse Assessment Sites
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...

