Related Experiment Video
Updated: Jan 6, 2026

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Operating room ventilation-Validation of reported data on 108 067 primary total hip arthroplasties in the Norwegian
Håkon Langvatn1,2, Christoffer Bartz-Johannessen1, Johannes Cornelis Schrama1
1The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, 5021, Norway.
Rationale, Aims, And Objectives:
The true effect of laminar airflow (LAF) systems on postoperative infection is disputed, partly due to uncertainty regarding the validity of ventilation data in register studies. The aim of this study was to validate the information on operating room (OR) ventilation reported by the orthopaedic surgeons to the Norwegian Arthroplasty Register (NAR) after primary total hip arthroplasty (THA).
Method:
Forty of the 62 public orthopaedic units performing primary THA in Norway during the period 1987-2015 were included. The hospitals' current and previous ventilation systems were evaluated in cooperation with the hospitals head engineer. We identified the type of ventilation system reported to the NAR and compared the information with the factual ventilation in the specific ORs at the time of primary THA.
Results:
A total of 108 067 primary THAs were eligible for assessment. None of the hospitals performed THA in true "greenhouse" (GH) ventilation. Fifty-seven percent of the primary THAs were performed in ORs with LAF and 43% in ORs with conventional, turbulent ventilation (CV). Comparing the reported data with the validated data, LAF was reported with a sensitivity of 86%, specificity of 89%, and positive predictive value (PPV) of 92%, with an accuracy of 88%. CV was reported with a sensitivity of 89%, specificity of 87%, and PPV of 84%, with an accuracy of 88%. The total, mean misreporting rate was 12%.
Conclusions:
Surgeons were not fully aware of what kind of ventilation system they operated in. This study indicates that conclusions based on ventilation data reported on THA in the NAR should not be interpreted without considering the inaccuracy of the data.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: