Related Experiment Video
Updated: Jan 6, 2026

Digital Analysis of Immunostaining of ZW10 Interacting Protein in Human Lung Tissues
Published on: May 1, 2019
Diagnostic concordance between whole slide imaging and conventional light microscopy in cytopathology: A systematic
Ilaria Girolami1, Liron Pantanowitz2, Stefano Marletta1
1Department of Pathology and Diagnostics, University and Hospital Trust of Verona, Verona, Italy.
Abstract:
Many studies have examined the diagnostic concordance of whole slide imaging (WSI) and light microscopy (LM) for surgical pathology. In cytopathology, WSI use has been more limited, mainly because of technical issues. The aim of this study was to review the literature and determine the overall diagnostic concordance of WSI and LM in cytopathology. A systematic search of PubMed, Scopus, and the Cochrane Library was performed, with data extracted from the included articles. A quality assessment of studies was performed with a modified Quality Assessment of Diagnostic Accuracy Studies 2 tool. The primary outcome was concordance for the diagnoses rendered by WSI and LM as shown by the concordance rate with the original diagnosis, intra-observer and interobserver concordance with the κ coefficient, or a percentage. Secondary outcomes included the time taken to reach a diagnosis and the quality and perception of WSI. A descriptive survey was provided. Among 1867 publications, a total of 19 studies (1%) were included. Overall, the concordance between WSI and the original diagnosis was 84.1%, the intra-observer concordance between WSI and LM was 92.5% with a κ coefficient of 0.66, and the interobserver κ coefficient was 0.69. The time to reach a diagnosis was longer with WSI in all studies. The quality of WSI was good, but diagnostic confidence and cytologist preference were higher for LM. In conclusion, the concordance of WSI with LM is acceptable and in line with systematic reviews in surgical pathology. However, the time required for scanning and technical issues represent barriers to complete adoption. It is foreseeable that technical advances and rigorous validation study design will help to improve the diagnostic concordance of WSI with LM in cytopathology.
Related Concept Videos
Confocal Fluorescence Microscopy
Three-Dimensional Microscopy in Microbiology
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...