Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Concurrent agreement between ActiGraphⓇ and activPALⓇ in measuring moderate to vigorous intensity physical activity
Long F R Lee1, Philippa M Dall1
1School of Health & Life Sciences, Glasgow Caledonian University, Cowcaddens Road, Glasgow G4 0BA, United Kingdom.
Abstract:
This study aimed to assess the ability of the activPALⓇ monitor (commonly used for measuring Sedentary Behaviour (SB), sitting or reclining with low energy expenditure while awake) to measure moderate to vigorous physical activity (MVPA), by assessing its agreement with the concurrent measurement by ActiGraphⓇ monitor (commonly used for measuring MVPA) to identify if a single monitor could be used to measure both MVPA and SB. A convenience sample of 24 adults (79% female; aged 23-60) wore an ActiGraphⓇ GT3X+ and an activPAL3Ⓡ concurrently for one day during free-living activities. Time spent in MVPA was calculated as an outcome measure using published methods (ActiGraphⓇ, n = 6; activPALⓇn = 4). Agreement was assessed between pairs of outcomes using the Bland & Altman method. Participants engaged in between 60 and 145 min of MVPA. The activPALⓇ method summing time walking with a cadence ≥100 steps/min underestimated MVPA compared with the ActiGraphⓇ but had the lowest aggregate bias (-16 min). Other activPALⓇ methods, based on acceleration counts and the embedded MET algorithm, overestimated MVPA compared to the ActiGraphⓇ. The study was limited by the lack of activPALⓇ acceleration count methods developed for adults. With the recommended methods, the activPALⓇ could be suitable for use as a single monitor to measure both SB and MVPA.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of blood pressure in brachial artery(two-step method)
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: