Related Experiment Video
Updated: Jan 5, 2026

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Development of Simple Methods to Reduce the Exposure of the Public to Radiation from Patients Who Have Undergone
Razi Muzaffar1, Elyse Koester2, Sarah Frye3
1Division of Nuclear Medicine, Department of Radiology, Saint Louis University, Saint Louis, Missouri.
Abstract:
At a time when reducing the radiation dose to patients and the public has become a major focus, we assessed the radiation exposure rate from patients after an 18F-FDG PET/CT scan and evaluated different interventions to reduce it. Methods: We enrolled 100 patients, divided into 2 groups. For both groups, the radiation dose rate was measured with an ionization survey meter immediately after the scan. For group 1, the patients then voided and their dose rate was measured again. For group 2, the patients waited 30 min before voiding, and we measured the dose rate before (group 2A) and after (group 2B) they voided. Results: In total, 74 of the 100 patients exceeded the 20 μSv/h (2 mR/h) threshold immediately after the scan. In group 1, the mean dose rate decreased by 20.0% from the postscan measurement, with 12 of 36 remaining at or above 20 μSv/h. In group 2A, the mean dose rate decreased by 23% from the postscan measurement, with 9 of 38 remaining at or above 20 μSv/h. In group 2B, the mean dose rate decreased by 35% from the postscan measurement, with 1 of 38 remaining at 20 μSv/h. Conclusion: Nearly 75% of patients undergoing an 18F-FDG PET/CT scan exceed 20 μSv/h when leaving the imaging facility. The most effective method to reduce radiation exposure was to have the patient void 30 min after the examination.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:02Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT