Related Experiment Video
Updated: Jan 5, 2026

Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol
Published on: September 7, 2018
Referenceless multi-channel signal combination: A demonstration in chemical-shift-encoded water-fat imaging
Simin Liu1, Peng Wu1,2, Haining Liu3
1Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
Purpose:
Without explicit coil sensitivity information acquired by means of a reference body coil, multi-channel signal combination for water-fat separation (WFS) can be challenging due to channel-dependent phase offsets and chemical-shift dependent phase shifts. This study aims to develop a referenceless, robust, accurate, and fast channel combination method for WFS.
Theory And Methods:
A dual-step multi-channel combination method is proposed. In the first step, channel-dependent phase offsets are estimated with a preliminary WFS estimation. In the second step, the multi-channel data are combined after removing phase offsets. Thereafter, WFS is performed to obtain final results. Numerical simulations (4-64 coils) and in vivo experiments (8, 16, 28 coils) at 3T field strength are conducted to compare the proposed method to previous methods. Channel combination with a body-coil scan serves as the reference for in vivo experiments.
Results:
The proposed method estimates channel-dependent phase offsets accurately. It shows improved robustness to phase singularities than weighted mean and adaptive reconstruction. It is faster than adaptive reconstruction (e.g., 25.45 versus 46.34 s with 28 coils) and the channel-by-channel WFS method (e.g., 21.77 versus 50.04 s with 8 coils). It provides comparable fat quantification accuracy to the reference under various reasonable signal-to-noise ratio conditions (e.g., Pearson correlation coefficient r = 0.981 with P < 0.01, for in vivo fat fractions using flip angle = 10°).
Conclusion:
The proposed referenceless channel combination method may be beneficial to both qualitative and quantitative water-fat imaging.
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)