Combined gadoxetic acid and gadobenate dimeglumine enhanced liver MRI: a parameter optimization study
Gesine Knobloch1, Timothy Colgan1, Xiaoke Wang2
1Department of Radiology, University of Wisconsin - School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI, 53705, USA.
Purpose:
To demonstrate the feasibility of combined delayed-phase gadoxetic acid (GA) and gadobenate dimeglumine (GD) enhanced liver MRI for improved detection of liver metastases, and to optimize contrast agent dose, timing, and flip angle (FA).
Methods:
Fourteen healthy volunteers underwent liver MRI at 3.0T at two visits during which they received two consecutive injections: 1. GA (Visit 1 = 0.025 mmol/kg; Visit 2 = 0.05 mmol/kg) and 2. GD (both visits = 0.1 mmol/kg) 20 min after GA administration. Two sub-studies were performed: Experiment-1 Eight subjects underwent multi-phase breath-held 3D-fat-saturated T1-weighted spoiled gradient echo (SGRE) imaging to determine the optimal imaging window for the combined GA + GD protocol to create a homogeneously hyperintense liver and vasculature ("plain-white-liver") with maximum contrast to muscle which served as a surrogate for metastatic lesions in both experiments. Experiment-2 Six subjects underwent breath-held 3D-fat-saturated T1-weighted SGRE imaging at three different FA to determine the optimal FA for best image contrast. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated.
Results:
Experiment-1 The combined GA + GD protocol created a homogeneously hyperintense liver and vasculature with maximum CNR liver/muscle at approximately 60-120 s after automatic GD-bolus detection. Experiment-2 Flip angles between 25° and 35° at a dose of 0.025 mmol/kg GA provided the best combination that minimized liver/vasculature CNR, while maximizing liver/muscle CNR. CNR performance to achieve a "plain-white-liver" was superior with 0.025 mmol/kg GA compared to 0.05 mmol/kg.
Conclusion:
Combined GA + GD enhanced T1-weighted MRI is feasible to achieve a homogeneously "plain-white-liver". Future studies need to confirm that this protocol can improve sensitivity of liver lesion detection in patients with metastatic liver disease.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography