Analysis of fan-stage gap-flow data to inform simulation of fan broadband noise

Sheryl Grace1, Ignacio Gonzalez-Martino2, Damiano Casalino3

  • 1Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA.

Related Concept Videos

Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
324
General External Flow Characteristics01:26

General External Flow Characteristics

The study of external flow is essential for creating structures and objects that interact efficiently and safely with moving fluids, such as air or water. When a body is immersed in a flowing fluid, it experiences two primary forces: drag, which opposes motion along the flow direction, and lift, which acts perpendicular to the flow. The shape, size, and orientation of the object influence these forces.Streamlined and Blunt Bodies in External FlowObjects in fluid flow are classified as...
490
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the power flow program computes...
773
Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
780
Bernoulli's Equation for Flow Normal to a Streamline01:16

Bernoulli's Equation for Flow Normal to a Streamline

Bernoulli's equation for flow normal to a streamline explains how pressure varies across curved streamlines due to the outward centrifugal forces induced by the fluid's curvature. The pressure is higher on the inner side of the curve, near the center of curvature, and decreases outward to balance these centrifugal forces.
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines. However, the...
1.2K