Related Experiment Video
Updated: Jan 5, 2026

Grossing of Non-neoplastic Globes, Including Fetal Eyes
Published on: May 30, 2025
Multimodal imaging features of intraocular foreign bodies
Andrew J Rong1, Kenneth C Fan1, Behrad Golshani2
1Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA.
Abstract:
Objective: To determine the imaging approach for evaluating intraocular foreign bodies (IOFBs) by comparing the ability of different modalities [plain film x-ray, computed tomography (CT), magnetic resonsance imaging (MRI), convetional ultrasound, and ultrasound biomicroscopy] to detect and characterize IOFBs.Methods & Design: Systematic review of the literature.Results: CT is the most practical first step for evaluating patients with suspected IOFBs because it can detect a wide range of IOFB types at small limitis of detection. MRI and ultrasound are best reserved as adjunctive tests in most cases although these tests may provide important insights especially with wood, plastic, and glass IOFBs. Imaging characteristics of metal, wood, glass, plastic, stone, concrete, and graphite IOFBs are reviewed.Conclusion: Understanding the limits of detection for each IOFB type and imaging modality as well as the characteristic features of different IOFBs is of paramount importance to optimizing the management of ocular trauma patients.
More Related Videos
10:14Author Spotlight: Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023
07:12Spatio-Temporal In Vivo Imaging of Ocular Drug Delivery Systems using Fiberoptic Confocal Laser Microendoscopy
Published on: September 27, 2021