Developement of health risk rating scale for indoor airborne fungal exposure

Anirban Chaudhuri1, Chiradeep Basu1, Subarna Bhattacharyya1

  • 1School of Environmental Studies, Jadavpur University, Kolkata, India.

Insights

Airborne fungal load in air-conditioned rooms was quantified, revealing Aspergillus and Penicillium as dominant species. A health risk rating scale was developed to assess indoor environments based on fungal presence and exposure factors.

Area of Science:

  • Environmental microbiology
  • Indoor air quality assessment
  • Fungal bioaerosols

Background:

  • Indoor environments can harbor significant airborne fungal loads.
  • Fungal growth-promoting substances (FGPS) contribute to indoor fungal proliferation.
  • Assessing health risks associated with indoor fungi is crucial for public health.

Purpose of the Study:

  • To quantify airborne fungal load in various air-conditioned indoor spaces.
  • To identify dominant fungal genera in the studied environments.
  • To develop a health risk rating scale for indoor fungal exposure.

Main Methods:

  • Air samples were collected using an Andersen Two-Stage Cascade Impactor.
  • Rose Bengal agar and Potato Dextrose agar media were used for fungal cultivation.
  • Risk factors including total spore load (CFU/m³), species diversity, human exposure, and FGPS were analyzed.

Main Results:

  • The most dominant fungal genera identified were Aspergillus and Penicillium.
  • Higher colony-forming units (CFU) were observed in a library and a computer room.
  • A health risk rating scale was successfully developed based on evaluated risk factors.

Conclusions:

  • Air-conditioned indoor environments, particularly libraries and computer rooms, can harbor substantial airborne fungal populations.
  • The developed risk rating scale provides a tool for assessing health risks associated with indoor fungal exposure.
  • Further research can refine the scale and inform public health interventions for improved indoor air quality.