Related Experiment Video
Updated: Jan 5, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Relationship between Lower Dose and Injection Speed of Iodinated Contrast Material for CT and Acute Hypersensitivity
Hyo Jung Park1, Jung Hee Son1, Tae-Bum Kim1
1From the Department of Radiology and Research Institute of Radiology (H.J.P., J.H.S., E.H.K., A.Y.K., S.H.P.) and Department of Allergy and Clinical Immunology (T.B.K., M.K.K.), University of Ulsan College of Medicine, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul 05505, South Korea; and Department of Radiology, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, South Korea (K.H.).
Abstract:
BackgroundThere are few data on the relationship between acute hypersensitivity reactions and the dose and injection rate of iodinated contrast material for CT.PurposeTo determine the relationship between lower dose and injection speed of iodinated contrast material for CT and the rate of acute hypersensitivity reactions.Materials and MethodsThis retrospective study included adults (age ≥18 years) undergoing nonionic iodinated contrast material-enhanced abdominal CT between August 2016 and January 2017 (control period) and between August 2017 and January 2018 (intervention period); all examinations were conducted in an outpatient setting. Compared with CT during the control period, CT during the intervention period involved a reduced dose of contrast material achieved by lowering the CT tube voltage. CT examinations in the control period were performed with 120 kVp, a contrast material dose of 2 mL/kg (maximum, 150 mL), and an injection speed of 3 or 4 mL/sec. CT examinations in the intervention period were performed with 100 kVp, a contrast material dose of 1.5 mL/kg (maximum, 130 mL), and an injection speed of 2.5 or 3 mL/sec. Per-examination rates of acute hypersensitivity reactions to iodinated contrast material were compared between the control and intervention periods with use of a multivariable Poisson regression model, the parameters of which were estimated by using generalized estimating equations with an independence correlation structure.ResultsA total of 21947 adults (mean age ± standard deviation, 59 years ± 12; 8797 women [40%]) underwent 25119 CT examinations during the control period; 23019 adults (mean age, 59 years ± 12; 9538 women [41%]) underwent 26491 CT examinations during the intervention period. The rate of acute hypersensitivity reactions was 1.42% (376 of 26491 examinations; 95% confidence interval [CI]: 1.28%, 1.57%) in the intervention period and 1.86% (468 of 25119 examinations; 95% CI: 1.70%, 2.04%) in the control period, with a multivariable-adjusted relative risk of 0.85 (95% CI: 0.74, 0.99; P = .03).ConclusionReduction in the dose and injection speed of iodinated contrast material for CT was associated with a lower rate of acute hypersensitivity reactions to iodinated contrast material.© RSNA, 2019Online supplemental material is available for this article.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions

