Experimental Tests on Fiber-Reinforced Alkali-Activated Concrete Beams Under Flexure: Some Considerations on the Behavior at Ultimate and Serviceability Conditions
Related Experiment Video
Updated: Jan 5, 2026

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Linda Monfardini1, Luca Facconi2, Fausto Minelli3
1DICATAM-Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, 25123 Brescia, Italy. l.monfardini001@unibs.it.
Abstract:
Alkali-activated concrete (AAC) is an alternative concrete typology whose innovative feature, compared to ordinary concrete, is represented by the use of fly ash as a total replacement of Portland cement. Fly ash combined with an alkaline solution and cured at high temperature reacts to form a geopolymeric binder. The growing interest in using AACs for structural applications comes from the need of reducing the global demand of Portland cement, whose production is responsible for about 9% of global anthropogenic CO2 emissions. Some research studies carried out in the last few years have proved the ability of AAC to replace ordinary Portland cement concrete in different structural applications including the construction of beams and panels. On the contrary, few experimental results concerning the structural effectiveness of fiber-reinforced AAC are currently available. The present paper presents the results of an experimental program carried out to investigate the flexural behavior of full-scale AAC beams reinforced with conventional steel rebars, in combination with fibers uniformly spread within the concrete matrix. The experimental study included two beams containing 25 kg/m3 (0.3% in volume) of high-strength steel fibers and two beams reinforced with 3 kg/m3 (0.3% in volume) of synthetic fibers. A reference beam not containing fibers was also tested. The discussion of the experimental results focuses on some aspects significant for the structural behavior at ultimate limit states (ULS) and serviceability limit states (SLS). The discussion includes considerations on the flexural capacity and ductility of the test specimens. About the behavior at the SLS, the influence of fiber addition on the tension stiffening mechanism is discussed, together with the evolution of post-cracking stiffness and of the mean crack spacing. The latter is compared with the analytical predictions provided by different formulations developed over the past 40 years and adopted by European standards.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Related Concept Videos
Fiber Reinforced Concrete
Design of Prismatic Beams for Bending
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Plastic Deformations