Related Experiment Video
Updated: Jan 5, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Bond Strength and Fracture Resistance of Flowable Bulk Fill Composite Posts and Cores in Endodontically Treated Teeth
Khoa V Pham1, Trang T T Huynh1
1Department of Operative Dentistry and Endodontics, Faculty of Odonto-Stomatology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Objectives:
Smart dentin replacement (SDR) is a new flowable bulk fill composite with many useful characteristics such as low viscosity and higher depth of cure. This study aimed to evaluate the bond strength and fracture resistance of flowable bulk fill composite posts and cores versus that of fiber posts and cores.
Materials And Methods:
Forty intact, extracted human maxillary central incisor roots were endodontically treated. Group A (n = 20) was prepared for the composite space and group B (n = 20) was prepared for the fiber post space. Group A and B were divided into two subgroups A1 and A2 and B1 and B2, respectively (10 roots for each subgroup). Root canal spaces of group A1 were filled with SDR composite, X-Post fiber post with Core X Flow composite was inserted into the root canal spaces of group B1. Group A2 was restored using SDR and group B2 was restored using post and core composite. Five hundred thermocycles were applied for the sample. Bond strength values were measured for segments in A1 and B1. Fracture force values were measured for specimens of A2 and B2.
Results:
No significant difference was observed between the two paired groups (A1 and B1) and (A2 and B2) in bond strength and fracture force values.
Conclusion:
SDR could be used for restoring endodontically treated teeth.
More Related Videos
Related Concept Videos
Bonding and Strength of Aggregate
Porosity in Cement Paste
The balance of water to cement in the mix is...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Additives and Fillers in Concrete
The...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Mortar Properties