Related Experiment Video
Updated: Jan 5, 2026

Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012
Classical pathway activity C3c, C4 and C1-inhibitor protein reference intervals determination in EDTA plasma
Benjamin Lopez1,2, Nicolas Bertier1, Emmanuel Ledoult1,3
1Department of Immunology, Lille University Hospital, Lille, France.
Introduction:
Reference intervals (RIs) for complement assays in EDTA plasma samples have not previously been published. The objectives of the present study were to validate and/or determine RIs for classical pathway (CP50) activity and C3c, C4 and C1 inhibitor protein (C1INH) assays and to assess the need for age-specific RIs in EDTA plasma.
Materials And Methods:
We retrospectively evaluated a cohort of 387 patients attending our university hospital and known to be free of complement-modifying diseases. The need for age partitioning was assessed and RIs were calculated according to the CLSI protocol.
Results:
No need for age partitioning was evidenced for CP50 activity, C3c and C4 concentrations and RIs (90% CI) were calculated from the pooled data: 35.4 (33.1-37.2) to 76.3 (73.7-83.6) U/mL for CP50 activity, 0.80 (0.75-0.87) to 1.64 (1.59-1.72) g/L for C3c, and 0.12 (0.10-0.14) to 0.38 (0.36-0.40) g/L for C4. Our results highlight a positive association between age and C1INH concentrations. We derived 3 age partitions (6 months to 30 years, 30-50 and > 50 years) and the related RIs: 0.20 (0.18-0.21) to 0.38 (0.36-0.40) g/L, 0.22 (0.20-0.24) to 0.39 (0.36-0.41) g/L and 0.25 (0.22-0.27) to 0.41 (0.40-0.43) g/L, respectively).
Conclusions:
The newly determined RIs for CP50 activity were higher than those provided by the manufacturer for EDTA plasma samples, whereas those for C3c and C4 RIs were similar to the values provided for serum samples. The C1INH concentration and activity were found to be associated with age and age-specific RIs are mandatory for this analyte.
More Related Videos
09:41Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
11:03Use of Capillary Electrophoresis Immunoassay to Search for Potential Biomarkers of Amyotrophic Lateral Sclerosis in Human Platelets
Published on: February 10, 2020
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric EDTA Titration Curves
EDTA: Indirect and Alkalimetric Titration
EDTA: Auxiliary Complexing Reagents
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...