Related Experiment Video
Updated: Jan 5, 2026

Author Spotlight: Repetitive Transcranial Magnetic Stimulation Combined with Movement Observation in Cerebral Palsy
Published on: August 9, 2024
Post-thrombotic syndrome in children: Measurement properties of CAPTSure, a new diagnostic tool
Maria Laura Avila1,2, Brian M Feldman1,2,3, Eleanor Pullenayegum2
1Department of Pediatrics The Hospital for Sick Children Toronto ON Canada.
Insights
The Clinical Assessment of Pediatric Post-Thrombotic Syndrome (CAPTsure) tool demonstrates excellent reliability and minimal measurement error for diagnosing and rating pediatric post-thrombotic syndrome (PTS). This makes it a dependable instrument for clinical use.
Area of Science:
- Pediatric medicine
- Vascular health
- Diagnostic tools
Background:
- Pediatric post-thrombotic syndrome (PTS) requires reliable assessment tools.
- The Clinical Assessment of Pediatric Post-Thrombotic Syndrome (CAPTsure) was developed for PTS diagnosis and severity rating.
- Validation of CAPTsure's reliability, measurement error, and minimal detectable change was necessary.
Purpose of the Study:
- To evaluate the reliability of the CAPTsure tool in pediatric patients.
- To determine the measurement error associated with CAPTsure.
- To establish the minimal detectable change for the CAPTsure score.
Main Methods:
- Children (0-18 years) with deep vein thrombosis (DVT) were assessed ≥6 months post-diagnosis.
- Two raters evaluated clinician assessment component (CC) reliability.
- Patients/proxies completed the symptoms component (SC) at baseline and 2 weeks later for test-retest reliability.
Main Results:
- High intraclass correlation coefficients (ICCs) were found for both CC (0.88-0.89) and SC (0.89-0.92) across extremities.
- Overall CAPTsure ICCs were excellent (0.92-0.93).
- Measurement error was low (1.7-4.3/100 points), with an 11-point change indicating significant severity alteration.
Conclusions:
- CAPTsure exhibits excellent reliability for assessing pediatric PTS.
- The tool demonstrates a small measurement error, enhancing its clinical utility.
- CAPTsure is reliable even when administered by non-hematologists.
Background:
CAPTsure (Clinical Assessment of PTS) is a new tool for diagnosis and severity rating of pediatric postthrombotic syndrome (PTS). Our objective was to test the reliability, measurement error, and minimal detectable change of CAPTSure.
Methods:
Children aged newborn to 18 years who sustained upper extremity or lower extremity deep vein thrombosis (DVT) were enrolled ≥ 6 months after DVT diagnosis. Patients were assessed by 2 raters to determine the reliability of the clinician assessment component (CC) of CAPTSure. Patients/proxies completed CAPTSure at baseline and approximately 2 weeks later to assess test-retest reliability of the symptoms component (SC).
Results:
Of 148 patients enrolled in the study; 30 had sustained either bilateral or both upper and lower extremity DVT. Hence, 178 extremities were assessed for PTS signs (86 upper extremity, 92 lower extremity). Intraclass correlation coefficient (ICC) for the CC was 0.89 (95% confidence interval [CI], 0.84-0.93) for upper extremity and 0.88 (95% CI, 0.83-0.92) for lower extremity. Nonclinicians performed 59% of measurements. Ninety-eight patients completed the SC at baseline and follow-up, for a total of 60 upper extremity and 61 lower extremity assessments. ICC for the SC was 0.89 (95% CI, 0.84-0.93) for upper extremity and 0.92 (0.87-0.95) for lower extremity. ICC for CAPTSure was 0.92 (95% CI, 0.87-0.95) for upper extremity and 0.93 (95% CI, 0.88-0.95) for lower extremity assessment. Measurement error ranged between 1.7 and 4.3 of 100 points. A change of approximately 11 of 100 points in CAPTSure score would be required to be confident that there was a change in PTS severity.
Conclusion:
CAPTSure has excellent reliability and a small measurement error, even when applied by nonhematologists.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies