Related Experiment Video
Updated: Jan 5, 2026

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
On-site evaluation of CT-based fractional flow reserve using simple boundary conditions for computational fluid
Yusuke Yoshikawa1, Masahiko Nakamoto2, Masanori Nakamura3
1Department of Cardiovascular Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
Abstract:
Fractional flow reserve (FFR) is an established method for diagnosing physiological coronary artery stenosis. A method for computing FFR using coronary computed tomography (CT) images was recently developed. However, its calculation requires off-site supercomputer analysis. Here, we report the preliminary result of a method using simple estimation of boundary conditions. The lumen boundaries of the coronary arteries were semi-automatically delineated using full width at half maximum of CT number profiles. The computational fluid dynamics (CFD) of the blood flow was performed using the boundary conditions of a fixed pressure at the coronary ostium and flow rates at each outlet. The total inflow at the coronary ostium was estimated based on the uniform wall shear stress hypothesis and corrected using a hyperemic multiplier to gain a hyperemic flow rate. The flow distribution from a parent vessel to the downstream daughter vessels was determined according to Murray's law. FFR estimated by CFD was calculated as FFRCFD = Pd/Pa. We collected patients who underwent coronary CT and coronary angiography followed by invasively measured FFR and compared FFRCFD with FFR. Sensitivity, specificity, and correlations were assessed. A total of 48 patients and 72 arteries were assessed. The correlation coefficient of FFRCFD with FFR was 0.56. The cut-off value was ≤ 0.80, sensitivity was 59.1%, and specificity was 94.0%. CFD-based FFR using simple boundary conditions for on-site clinical computation provided FFRCFD values that were moderately correlated with invasively measured FFR.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
10:58Parametric Optimization Design Method for Friction Plates of Hydro-Viscous Clutches
Published on: July 22, 2025
Related Concept Videos
Rapidly Varying Flow
Typical Model Studies
Conservation of Mass in Finite Cotrol Volume
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
Bernoulli's Equation for Flow Along a Streamline
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fast Decoupled and DC Powerflow