Related Experiment Video
Updated: Jan 5, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
When Experts Fail: Use of a Short Turning Radius Colonoscope Facilitates Successful Completion of Colonoscopy in
Mohit Girotra1, Saurabh Sethi1, Monique T Barakat1
1Division of Gastroenterology and Hepatology, Stanford University School of Medicine, 300 Pasteur Drive, MC: 5244, Stanford, CA, 94305, USA.
Background:
Rates of incomplete colonoscopy in non-expert settings range up to 13%. Expert colonoscopists can complete ~ 95% colonoscopies when other endoscopists fail; however, a small number remain incomplete even in expert hands, typically due to bowel fixity.
Aims:
Pentax Retroview™ (EC-3490TLi) is a new slim colonoscope with a short turning radius (STR) and greater tip deflection (210°), which allows easy maneuverability across sharply angulated/fixed colonic bends. We evaluated the utility of this colonoscope for completing colonoscopies that fail even in the hands of expert colonoscopists.
Methods:
Retrospective chart review was performed, and main outcomes measured included cecal intubation rate, lesions detected, dosage of sedation used, and complications.
Results:
Using the STR colonoscope, complete colonoscopy to the cecum was possible in 34/37 patients (91.9%). No loss of lumen/blind advancement was necessary in any of the procedures. No adverse events occurred. Among the completed colonoscopies, 6/34 (17.6%) patients had adenomas, all proximal to the site of prior failure, including one advanced adenoma. All failures (n = 3, 8.1%) had a history of cancer surgeries, with peritoneal carcinomatosis/extensively fixed/frozen bowel (two patients) and an additional diverticular stricture with colo-vesical fistula (one patient).
Conclusion:
STR colonoscope facilitates completion of a high proportion (91.9%) of colonoscopies that previously failed in expert hands. Its STR allows easy maneuverability across segments of sharp angulation with bowel fixity without need for blind advancement. The use of this colonoscope led to the detection of adenomas in 17.6% of patients, all proximal to the site of prior failed colonoscopy.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
08:26Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...