Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Dual-mode hydrophilic interaction normal phase and reversed phase liquid chromatography of polar compounds on a
1Department of Analytical Chemistry, University of Pardubice, Pardubice, Czech Republic.
Abstract:
Adopting a stationary phase convention circumvents problematic definition of the boundary between the stationary and the mobile phase in the liquid chromatography, resulting in thermodynamically consistent and reproducible chromatographic data. Three stationary phase definition conventions provide different retention data, but equal selectivity: (i) the complete solid phase moiety; (ii) the solid porous part carrying the active interaction centers; (iii) the volume of the inner column pores. The selective uptake of water from the bulk aqueous-organic mobile phase significantly affects the volume and the properties of polar stationary phases. Some polar stationary phases provide dual-mode retention mechanism in aqueous-organic mobile phases, reversed-phase in the water-rich range, and normal-phase at high concentrations of the organic solvent in water. The linear solvation energy relationship model characterizes the structural contributions of the non-selective and selective polar interactions both in the water-rich and organic solvent-rich mobile phases. The inner-pore convention provides a single hold-up volume value for the retention prediction on the dual-mode columns over the full mobile phase range. Using the dual-mode monolithic polymethacrylate zwitterionic micro-columns alternatively in each mode in the first dimension of two-dimensional liquid chromatography, in combination with a short reversed-phase column in the second dimension, provides enhanced sample information.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Instrumentation