Background:
Wheat allergy is relatively common and the associated clinical manifestations depend on the involved molecular allergens as well as on the way of exposure. Different symptoms have been described: wheat-dependent exercise-induced anaphylaxis (WDEIA), atopic dermatitis (AD) and pollen rhinitis (PR). Traditional diagnostic methods do not allow accurate molecular identification of the allergens that are essential for risk assessment and for the choice of the most adapted treatment.
Methods:
Standardized total protein extracts obtained from wheat seeds were separated by 2D electrophoresis. Twenty-one sera with high wheat-specific immunoglobulin E (sIgE) levels were classified into three patients groups based on their clinical profile. These sera were tested by Western blot on 2D separated standardized wheat protein extract and their sIgE sensitization profiles were compared.
Results:
Specific sensitization profiles were identified for each phenotype group. For WDEIA, protein spots around 37 kDa (pH 6-9) and 37-50 kDa (pH 5-6) were identified. For AD, spots were observed around 50 kDa (pH 9), 10 kDa (pH 9) and 20 to 75 kDa (pH3). For PR, specific spots were located around 90 kDa (pH 9). The mass spectrometry (UHPLC-MS/MS) analysis of these identified spots pointed out several potential interesting allergens: Tri a 26, Tri a bA, Tri a 34, Tri a tritin.
Conclusions:
The present study allowed the identification of different protein areas specific to these studied groups. The protein spots of interest were identified by UHPLC-MS/MS. It has been possible to establish a link between a specific symptomatology and the newly identified responsible allergens.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
07:10Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
Published on: April 21, 2019
Related Concept Videos
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...