Related Experiment Video
Updated: Jan 5, 2026

Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Improving the Reliability and Accuracy of Ammonia Quantification in Electro- and Photochemical Synthesis
Guo Yi Duan1, Yuan Ren1, Yang Tang1
1National Fundamental Research Laboratory of New Hazardous Chemicals Assessment and Accident Analysis, Institute of Applied Electrochemistry, Beijing University of Chemical Technology, Beijing, 100029, P.R. China.
Abstract:
The reliable and accurate quantification of ammonia in electrochemical and photochemical experiments has been a technical challenge owing to the extremely low concentration of generated ammonia, interference from trace amounts of cations and organic compounds, and ammonia contamination from various sources. As a result, overestimation and significant errors may happen in many research works. Herein, accuracy and precision of ion chromatography (IC) are evaluated at different pH; excellent performance with a low detection limit (<2 μg L-1 ) under acidic and neutral conditions is found, whereas the linearity is unsatisfactory in the low NH4 + concentration range (0-100 μg L-1 ) under alkaline conditions. High concentrations of Li+ and Na+ are difficult to separate from NH4 + in conventional IC, but this can be solved by employing a high-exchange-capacity column or gradient elution. The interference effects of 14 common transition metal cations and 6 common organic compounds on the quantification of ammonium with low-level concentration (500 μg L-1 ) using IC are systematically investigated, and the results demonstrate good robustness. The overestimation caused by ammonia contamination from reagent water, surroundings, and even the analytical grade of inorganic and organic reagents are confirmed and the results indicate the necessity to prepare and test fresh electrolyte solutions before each experiment, owing to the high sensitivity of acidic and neutral solutions to ammonia contamination from the surroundings. The ammonization of a Nafion membrane during experiments and the underestimation in quantification are also discussed. Finally, a reliable level of synthesized ammonia is identified and some recommendations are presented to improve the reliability and accuracy of ammonia quantification.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Amperometry: Overview
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Interference
Electrogravimetric Analysis: Overview
To test the completeness of the...

