Related Experiment Video
Updated: Jan 5, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Multicenter Safety and Practice for Off-Label Diagnostic Use of Ferumoxytol in MRI
Kim-Lien Nguyen1, Takegawa Yoshida1, Nikhita Kathuria-Prakash1
1From the Diagnostic Cardiovascular Imaging Research Laboratory, Department of Radiological Sciences, David Geffen School of Medicine at UCLA, 300 Medical Plaza, Suite B119, Los Angeles, CA 90095 (K.L.N., T.Y., P.H., J.P.F.); Division of Cardiology, David Geffen School of Medicine at UCLA and VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N., N.K.); Department of Radiology (I.H.Z., M.R.B.), Center for Advanced Magnetic Resonance Development (I.H.Z., M.R.B.), and Division of Gastroenterology, Department of Medicine (M.R.B.), Duke University Medical Center, Durham, NC; Department of Diagnostic Radiology and Neurology, Oregon Health Sciences University, Portland, Ore (C.G.V.); British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, Scotland (S.I.S., D.E.N.); Department of Imaging, Cedars-Sinai Medical Center, Los Angeles, Calif (R.S.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Ill (C.K.R., L.M.G.); Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (C.K.R., L.M.G.); Institute of Cardiovascular and Medical Sciences, University of Glasgow, Scotland (S.S., A.R.); Division of Cardiology, Department of Pediatrics and Radiology, Children's Hospital of Philadelphia, Philadelphia, Pa (K.K.W., M.A.F.); Department of Radiology, University of Wisconsin, Madison, Wis (L.M.G., M.L.S.); Department of Radiology, University of California, San Francisco and VA San Francisco Healthcare System, San Francisco, Calif (D.S., M.D.H.); Department of Radiology, Weill Medical College of Cornell University, New York, NY (M.R.P.); Department of Radiology, NHS Greater Glasgow and Clyde, and Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, Scotland (G.H.R.); and Department of Neurology and Neurosurgery, Oregon Health Sciences University and VA Portland Healthcare System, Portland, Ore (E.A.N.).
Abstract:
Background Ferumoxytol is approved for use in the treatment of iron deficiency anemia, but it can serve as an alternative to gadolinium-based contrast agents. On the basis of postmarketing surveillance data, the Food and Drug Administration issued a black box warning regarding the risks of rare but serious acute hypersensitivity reactions during fast high-dose injection (510 mg iron in 17 seconds) for therapeutic use. Whereas single-center safety data for diagnostic use have been positive, multicenter data are lacking. Purpose To report multicenter safety data for off-label diagnostic ferumoxytol use. Materials and Methods The multicenter ferumoxytol MRI registry was established as an open-label nonrandomized surveillance databank without industry involvement. Each center monitored all ferumoxytol administrations, classified adverse events (AEs) using the National Cancer Institute Common Terminology Criteria for Adverse Events (grade 1-5), and assessed the relationship of AEs to ferumoxytol administration. AEs related to or possibly related to ferumoxytol injection were considered adverse reactions. The core laboratory adjudicated the AEs and classified them with the American College of Radiology (ACR) classification. Analysis of variance was used to compare vital signs. Results Between January 2003 and October 2018, 3215 patients (median age, 58 years; range, 1 day to 96 years; 1897 male patients) received 4240 ferumoxytol injections for MRI. Ferumoxytol dose ranged from 1 to 11 mg per kilogram of body weight (≤510 mg iron; rate ≤45 mg iron/sec). There were no systematic changes in vital signs after ferumoxytol administration (P > .05). No severe, life-threatening, or fatal AEs occurred. Eighty-three (1.9%) of 4240 AEs were related or possibly related to ferumoxytol infusions (75 mild [1.8%], eight moderate [0.2%]). Thirty-one AEs were classified as allergiclike reactions using ACR criteria but were consistent with minor infusion reactions observed with parenteral iron. Conclusion Diagnostic ferumoxytol use was well tolerated, associated with no serious adverse events, and implicated in few adverse reactions. Registry results indicate a positive safety profile for ferumoxytol use in MRI. © RSNA, 2019 Online supplemental material is available for this article.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging