Related Experiment Video
Updated: Jan 5, 2026

Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
Published on: January 30, 2020
Kinetics of manual and automated mechanical chest compressions
Riccardo Colombo1, Tommaso Fossali1, Davide Ottolina1
1Department of Anesthesia and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario, University of Milan, Milan, Italy.
Aim:
Early onset of adequate chest compression is mandatory for cardiopulmonary resuscitation (CPR) following cardiac arrest. Transmission of forces from chest strain to the heart may be variable between manual and mechanical chest compressions. Furthermore, automated mechanical chest devices can deliver an active decompression, thus improving the venous return to the heart. This pilot study investigated the kinetics of cardiac deformation during these two CPR methods.
Methods:
Transesophageal echocardiographic analysis of the right ventricular wall behind the sternum during CPR was assessed during manual and mechanical chest compression in adult patients admitted to the emergency department for out-of-hospital cardiac arrest.
Results:
9 patients had manual and 11 mechanical chest compression. Mechanical chest compression was characterized by greater right ventricular lateral wall displacement [with a median (IQR) of 3.7 (3.12-4.27) vs. 2.53 (2.27-2.6) cm, p < 0.0001], and lower rising time [123 (102-169) vs. 187 (164-215) ms, p = 0.002], relaxing time [109 (102-127) vs. 211 (133-252) ms, p = 0.0003], compression rate [100.6 (99.6-102.2) vs. 131.9 (125.4-151.4) bpm, p < 0.0001], with compression-decompression time ratio of [1.04 (0.86-1.1) vs. 0.86 (0.78-0.96), p = 0.046].
Conclusion:
Mechanical compared to manual chest compression delivered a more rapid compression and decompression of the cardiac structures at an adequate rate, with broader inward-outward movement of the ventricular walls suggesting greater emptying and filling of the ventricles. Transesophageal echocardiography may be a useful tool to assess the adequacy of chest compression without CPR interruption.
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation III: AED Use
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Mechanism of Breathing III: The Accessory Muscles
The respiratory system is a complex network that relies on primary respiratory muscles like the diaphragm, but also involves accessory muscles to enhance lung expansion and airflow during both inhalation and exhalation.
Enhancing Inhalation with Accessory Muscles:
Accessory muscles such as the sternocleidomastoid, scalene, intercostal, and abdominal muscles are crucial when additional respiratory effort is required, such as during deep...
Assessment of blood pressure in brachial artery(two-step method)