Related Experiment Video
Updated: Jan 5, 2026

A Layered Mounting Method for Extended Time-Lapse Confocal Microscopy of Whole Zebrafish Embryos
Published on: January 14, 2020
Standardized mounting method of (zebrafish) embryos using a 3D-printed stamp for high-content, semi-automated
David Simon Kleinhans1, Virginie Lecaudey2
1Department of Developmental Biology of Vertebrates, Institute for Cell biology and Neuroscience, Goethe University, Max-von-Laue-Str. 13, 60438, Frankfurt am Main, Germany.
Background:
Developmental biology relies to a large extent on the observation and comparison of phenotypic traits through time using high resolution microscopes. In this context, transparent model organisms such as the zebrafish Danio rerio in which developing tissues and organs can be easily observed and imaged using fluorescent proteins have become very popular. One limiting factor however is the acquisition of a sufficient amount of data, in standardized and reproducible conditions, to allow robust quantitative analysis. One way to improve this is by developing mounting methods to increase the number of embryos that can be imaged simultaneously in near-to-identical orientation.
Results:
Here we present an improved mounting method allowing semi-automated and high-content imaging of zebrafish embryos. It is based on a 3D-printed stamp which is used to create a 2D coordinate system of multiple μ-wells in an agarose cast. Each μ-well models a negative of the average zebrafish embryo morphology between 22 and 96 h-post-fertilization. Due to this standardized and reproducible arrangement, it is possible to define a custom well plate in the respective imaging software that allows for a semi-automated imaging process. Furthermore, the improvement in Z-orientation significantly reduces post-processing and improves comparability of volumetric data while reducing light exposure and thus photo-bleaching and photo-toxicity, and improving signal-to-noise ratio (SNR).
Conclusions:
We present here a new method that allows to standardize and improve mounting and imaging of embryos. The 3D-printed stamp creates a 2D coordinate system of μ-wells in an agarose cast thus standardizing specimen mounting and allowing high-content imaging of up to 44 live or mounted zebrafish embryos simultaneously in a semi-automated, well-plate like manner on inverted confocal microscopes. In summary, image data quality and acquisition efficiency (amount of data per time) are significantly improved. The latter might also be crucial when using the services of a microscopy facility.
More Related Videos
07:06Semi-automated Imaging of Tissue-specific Fluorescence in Zebrafish Embryos
Published on: May 17, 2014
08:33Author Spotlight: Strategies for Mounting Zebrafish Embryos for High-Resolution Multiview Light-Sheet Microscopy — Techniques for Imaging and Image Reconstruction
Published on: July 19, 2024