Magnetic resonance imaging (MRI) versus single photon emission computed tomography (SPECT/CT) in painful total hip
Henrik C Bäcker1,2, Isabelle Steurer-Dober3, Martin Beck2
1Radiology and Nuclear Medicine, Cantonal Hospital Lucerne, Lucerne, Switzerland.
Objective:
To investigate the value of MRI in comparison to single photon emission computed tomography (SPECT)/CT in patients with painful hip arthroplasties.
Methods:
A prospective, multi-institutional study was performed. Therefore, 35 consecutive patients (21 female, 14 male, mean age 61.8 ± 13.3 years) with 37-painful hip arthroplasties were included. A hip surgeon noted the most likely diagnosis based on clinical examination and hip radiographs. Then, MRI and SPECT/CT of the painful hips were acquired. MRI and SPECT/CT were assessed for loosening, infection, fracture, tendon pathology and other abnormalities. Final diagnosis and therapy was established by the hip surgeon after integration of MRI and SPECT/CT results. The value of MRI and SPECT/CT for diagnosis was assessed with a 3-point scale (1 = unimportant, 2 = helpful, 3 = essential).
Results:
Loosening was observed in 13/37 arthroplasties (6 shaft only, 6 cup only, 1 combined). Sensitivity, specificity, positive predictive value and negative predictive value for loosening of MRI were 86%/88%/60%/100% and of SPECT/CT 93%/97%/90%/100%, respectively. MRI and SPECT/CT diagnosed infection correctly in two of three patients and fractures in two patients, which were missed by X-ray. MRI detected soft tissue abnormalities in 21 patients (6 bursitis, 14 tendon lesions, 1 pseudotumor), of which only 1 tendon abnormality was accurately detected with SPECT/CT. All 5 arthroplasties with polyethylene wear were correctly diagnosed clinically and with both imaging modalities. MRI and SPECT/CT were judged as not helpful in 0/0%, as helpful in 16%/49% and essential in 84%/51%.
Conclusion:
In patients with painful hip arthroplasty SPECT/CT is slightly superior to MR in the assessment of loosening. MRI is far superior in the detection of soft tissue, especially tendon pathologies.
Advances In Knowledge:
To our knowledge this is the first prospective, multiinstitutional study which compares MRI with SPECT/CT in painful hip arthroplasties. We found that MRI is far superior in the detection of soft tissue pathologies, whereas SPECT/CT remains slightly superior regarding loosening.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography