Radon and moisture impacts from interventions integrated with housing energy retrofits
Paul W Francisco1, Stacy Gloss1, Jonathan Wilson2
1University of Illinois at Urbana-Champaign, Champaign, IL, USA.
Abstract:
Energy retrofits can reduce air exchange, raising the concern of whether indoor radon and moisture levels could increase. This pre/post-intervention study explored whether simple radon interventions implemented in conjunction with energy retrofits can prevent increases in radon and moisture levels. Treatment homes (n = 98) were matched with control (no energy retrofits or radon intervention) homes (n = 12). Control homes were matched by geographic location and foundation type. t-tests were used to determine whether post-energy retrofit radon and moisture level changes in treatment homes significantly differed from those in control homes. The radon interventions succeeded in preventing statistically significant increases in first floor radon using arithmetic (p = 0.749) and geometric means (p = 0.120). In basements, arithmetic (p = 0.060) and geometric (p = 0.092) mean radon levels statistically significantly increased, consistent with previous studies which found that basement radon levels may increase even if first floor levels remain unchanged. Changes in infiltration were related to changes in radon (p = 0.057 in basements; p = 0.066 on first floors). Only 58% of the change in infiltration was due to air sealing, with the rest due to weather changes. There was no statistically significant association between air sealing itself and radon levels on the first floor (p = 0.664). Moisture levels also did not significantly increase.
More Related Videos
09:39Production and Testing of Moisture Behavior and Thermal Properties of Rapeseed Straw and Ganoderma resinaceum Mycelium Bio-Composites
Published on: September 5, 2025
11:19Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Mortar Joint Deterioration in Masonry
The...
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Radiation: Applications
The average...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Masonry Cavity Walls
Maintaining a clean cavity during construction...