Quantitative Assessment of Breast Density: Transmission Ultrasound is Comparable to Mammography with Tomosynthesis
Rajni Natesan1,2, James Wiskin2, Sanghyeb Lee2
1Department of Diagnostic Radiology, MD Anderson Cancer Center, Houston, Texas. rnatesan@mdanderson.org.
Abstract:
Elevated breast density is among the strongest independent predictors of breast cancer. Breast density scores are critical inputs in models used to calculate a patient's lifetime risk of developing breast cancer. Today, the only FDA-cleared technology for assessing breast density uses mammography. An alternative modality for breast density quantification is 3D transmission ultrasound (TU). In this retrospective study, we compared automated breast density calculations derived from TU using quantitative breast density (QBD) and mammography with tomosynthesis using VolparaDensity 3.1 for 225 breasts. Pearson correlation coefficients (r) and intraclass correlation coefficients were compared. Subset analyses of extremely dense breasts, premenopausal, and postmenopausal breasts were also performed. Comparative analysis between radiologist-derived density assessment and objective automated scores was performed. Calculations from TU and mammography with tomosynthesis for breast density, total breast volume (TBV), and fibroglandular volume (FGV) were strongly correlated (r = 0.91, 0.92, and 0.67, respectively). We observed moderate absolute agreement for FGV and breast density, and strong absolute agreement for TBV. A subset of 56 extremely dense breasts showed similar trends, however with lower breast density agreement in the subset than in the full study. No significant difference existed in density correlation between premenopausal and postmenopausal breasts across modalities. QBD calculations from TU were strongly correlated with breast density scores from VolparaDensity. TU systematically measured higher FGV and breast density compared with mammography, and the difference increased with breast density. IMPACT: TU of the breast can accurately quantify breast density comparable with mammography with tomosynthesis.
More Related Videos
13:43Intraductal Delivery and X-ray Visualization of Ethanol-Based Ablative Solution for Prevention and Local Treatment of Breast Cancer in Mouse Models
Published on: April 1, 2022
08:08Quantification of Breast Cancer Cell Invasiveness Using a Three-dimensional 3D Model
Published on: June 11, 2014
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography