Related Experiment Video
Updated: Jan 5, 2026

Confirmation of Myocardial Ischemia and Reperfusion Injury in Mice Using Surface Pad Electrocardiography
Published on: November 24, 2016
Long-Term Prognostic Value of Less-Stringent Electrocardiographic Q Waves and Fourth Universal Definition of
Christoffer Polcwiartek1, Kristian Kragholm2, Daniel J Friedman3
1Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark; Unit of Epidemiology and Biostatistics, Aalborg University Hospital, Aalborg, Denmark; Division of Cardiology, Duke University Medical Center, Durham, NC, USA; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark.
Background:
The Fourth Universal Definition of Myocardial Infarction defines electrocardiographic Q waves as duration ≥30 ms and amplitude ≥1 mm or QS complex in 2 contiguous leads. However, current taskforce criteria may be overly restrictive. Therefore, we investigated the association of isolated, lenient, or strict Q waves with long-term outcome.
Methods:
From 2001 to 2015, we included Danish primary care patients with digital electrocardiograms (ECGs) that were evaluated for Q waves. If none occurred, patients had no Q waves. If no other contiguous Q wave occurred, patients had isolated Q waves. If another contiguous Q wave occurred meeting only 1 criterion (≥30 ms and <1 mm or <30 ms and ≥1 mm), patients had lenient Q waves. If another contiguous Q wave occurred, patients had strict Q waves.
Results:
Of 365,206 patients, 87,957 had isolated, lenient, or strict Q waves (24%; median age, 61 years; male, 48%), and 277,249 had no Q waves (76%; median age, 53 years; male, 42%). Mortality risk was increased with isolated (all-cause adjusted hazard ratio [aHR], 1.33; 95% confidence interval [CI], 1.29-1.37; cardiovascular-cause aHR, 1.78; 95% CI, 1.70-1.87), lenient (all-cause aHR, 1.41; 95% CI, 1.33-1.50; cardiovascular-cause aHR, 1.78; 95% CI, 1.63-1.94), or strict (all-cause aHR, 1.64; 95% CI, 1.57-1.72; cardiovascular-cause aHR, 2.70; 95% CI, 2.52-2.89) Q waves compared with no Q waves. Highest mortality risk was associated with lenient or strict Q waves in anteroseptal leads.
Conclusions:
This large contemporary analysis suggests that less-stringent Q-wave criteria carry prognostic value in predicting adverse outcome among primary care patients.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Myocarditis II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome I: Introduction

