A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Pain monitor: reality or fantasy in ambulatory patients
Borzoo Farhang1, Donald M Mathews
1Department of Anesthesiology, Larner College of Medicine, University of Vermont, Burlington, Vermont, USA.
Purpose Of Review:
In an unconscious patient, there can be significant challenges to monitoring nociception and proper dosing of analgesic medications. The traditional measures of intraoperative nociception have poor sensitivity and specificity with little predictive value in postoperative outcomes such as postoperative pain, opioid-induced side effects, length of stay or incidence of opioid use disorder. To date, several monitoring modalities are in development to establish objective measures of the balance between nociception and analgesia with the goal of guiding anesthesiologists and improve patient outcomes. In this review, some of the most promising monitoring modalities are discussed with the most recent findings.
Recent Findings:
Multiple modalities are beginning to demonstrate utility compared with traditional care. Most, but not all, of these studies show decreased intraoperative opioid use and some show lower pain scores and opioid requirements in the postanesthesia care unit.
Summary:
Recent evidence points to promising efficacy for these monitoring modalities; however, this field is in its infancy. More investigation is required to demonstrate differences in outcome compared with traditional care, and these differences need to be of sufficient import to achieve widespread adoption.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...