The method of calibration model transfer by optimizing wavelength combinations based on consistent and stable
Liguo Zhang1, Yongqi Li1, Wen Huang2
1College of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China.
Abstract:
Basing on the wavelengths with consistent and stable spectral signals between spectrometers, wavelength combinations were screened by different methods to obtain robust and simple near infrared spectra (NIR) calibration models that can be shared by slave spectrometers directly. Firstly, the wavelength set of Usc, at which the spectral signals between spectrometers are consistent and stable, was obtained by the method of screening the wavelengths with consistent and stable signals between spectrometers (SWCSS for short). Then, the wavelength set of Uscr whose spectral responses are correlated with dependent variables strongly was selected from Usc. Basing on Uscr, the methods of uninformative variable elimination (UVE), variable importance in projection (VIP) and selectivity ratio (SR) were applied to further screen optimal wavelength sets to obtain better NIR calibration models. These sets were recorded as UscrUVE, UscrVIP and UscrSR, respectively. The NIR partial least squares (PLS) models for predicting total alkaloids content of tobacco leaves were built on the three optimal wavelength sets, and named as UscrUVE-PLS, UscrVIP-PLS, UscrSR-PLS, respectively. Both UscrUVE-PLS and UscrVIP-PLS give satisfactory prediction errors for master and slave samples, and work better than the PLS model built on the whole wavelengths (WW-PLS) after piecewise direct standardization (PDS) calibration. The results show that further optimizing wavelength combinations based on consistent and stable spectral information cannot only simplify PLS models and improve the models' efficiency, but also ensure the models' accuracy when they are transferred to slave spectrometers. Wavelength selection based on the whole wavelengths without considering spectra consistency between spectrometers can improve the performance of the calibration models on the master spectrometer but cannot ensure the prediction accuracy of the slave samples.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
10:00Calibration of Vector Network Analyzer for Measurements in Radio Frequency Propagation Channels
Published on: June 2, 2020
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...