Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Assessment of Upper Limb Physiological Features in Patients with Lymphedema After Breast Surgery Using Multiple
Motohiro Kojima1, Chisako Yamauchi1,2, Shunsuke Oyamada3
1Division of Pathology, Exploratory Oncology Research and Clinical Trial Center, National Cancer Center, Chiba, Japan.
Abstract:
Objective assessment of upper limb physiological features may allow for early detection and proper intervention for lymphedema after breast surgery. However, the development of diagnostic instruments and standard measurement procedures are required. Four instruments (Venustron, Softmeasure, Myoton Pro, and iBDent), tape measurement, and water volumetry were investigated in this study. Inter-limb differences in physiological data were obtained from 40 patients with lymphedema after breast surgery and 38 control subjects. Four instruments and tape measurements were performed at four points. Inter-limb differences between patients with lymphedema and control subjects were determined. All measurements took <20 minutes with minimal pain reported. Inter-limb differences in water volumetry and tape measurements, especially when measured at 5 cm distal to the cubital fossa, were increased in International Society of Lymphology (ISL) stage II cases. All four instruments showed high reproducibility in standard silicon sample measurement. On the other hand, data from human samples were varied, and the utility for assessment of lymphedema was not determined. Water volumetry and tape measurement at 5 cm distal to the cubital fossa were useful to assess lymphedema in ISL stage II cases. Four instruments used in this study were feasible in clinical practice. In addition, inconsistent data from human tissue were not due to sensor limitations, rather, acquisition of accurate data from human tissue seemed to be difficult due to anatomical factors. In addition to high-quality sensor, development of system that produce accurate and reproducible results from human tissue is required.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Arteries of the Upper Limbs
Peripheral Artery Disease V: Postoperative Nursing Management