Related Experiment Video
Updated: Jan 4, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
An Improved Ion Chromatographic Method for Fast and Sensitive Determination of Hexavalent Chromium and Total Chromium
Thyagarajan Shanmugam1, Joseph Selvaraj2, Uvaraj Mani1
1Metrohm India Limited, Application Laboratory, 3&4 Fourrts Avenue, Chennai, Tamil Nadu, India.
Abstract:
Chromium exists in its two stable oxidation states including trivalent chromium (Cr (III)) and hexavalent chromium (Cr (VI)) in natural waters. Chromium is an essential micronutrient in the trivalent form; however, the hexavalent form of chromium is considered to be a carcinogen. It is important to determine the chromium content along with speciation. There are a number of methods available for chromium determination. Speciation of chromium is essential to know the exact composition of chromium. Ion exchange chromatography is one of the techniques used to determine Cr (VI). The proposed method can be used to perform the speciation of Cr (III) and Cr (VI). It is a two-step process: first Cr (VI) is determined, followed by total chromium determination by treating the sample with potassium permanganate solution to oxidize the Cr (III) present in the sample to Cr (VI) and determining it as Cr (VI). Conductivity detector is used for the detection. Addition of potassium permanganate solution to the ground water samples for oxidizing the Cr (III) to Cr (VI) is the newly adopted sample preparation technique. The effect of potassium permanganate oxidation is studied in detail in the proposed method. This method can be used for chromium speciation in river water and ground water samples.
More Related Videos
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...