Related Experiment Video
Updated: Jan 4, 2026

Rare Event Detection Using Error-corrected DNA and RNA Sequencing
Published on: August 3, 2018
Accuracy of de novo assembly of DNA sequences from double-digest libraries varies substantially among software
Melanie E F LaCava1,2, Ellen O Aikens1,3, Libby C Megna1,4
1Program in Ecology, University of Wyoming, Laramie, WY, USA.
Abstract:
Advances in DNA sequencing have made it feasible to gather genomic data for non-model organisms and large sets of individuals, often using methods for sequencing subsets of the genome. Several of these methods sequence DNA associated with endonuclease restriction sites (various RAD and GBS methods). For use in taxa without a reference genome, these methods rely on de novo assembly of fragments in the sequencing library. Many of the software options available for this application were originally developed for other assembly types and we do not know their accuracy for reduced representation libraries. To address this important knowledge gap, we simulated data from the Arabidopsis thaliana and Homo sapiens genomes and compared de novo assemblies by six software programs that are commonly used or promising for this purpose (ABySS, CD-HIT, Stacks, Stacks2, Velvet and VSEARCH). We simulated different mutation rates and types of mutations, and then applied the six assemblers to the simulated data sets, varying assembly parameters. We found substantial variation in software performance across simulations and parameter settings. ABySS failed to recover any true genome fragments, and Velvet and VSEARCH performed poorly for most simulations. Stacks and Stacks2 produced accurate assemblies of simulations containing SNPs, but the addition of insertion and deletion mutations decreased their performance. CD-HIT was the only assembler that consistently recovered a high proportion of true genome fragments. Here, we demonstrate the substantial difference in the accuracy of assemblies from different software programs and the importance of comparing assemblies that result from different parameter settings.
More Related Videos
13:03Robust DNA Isolation and High-throughput Sequencing Library Construction for Herbarium Specimens
Published on: March 8, 2018
12:08Hybrid De Novo Genome Assembly for the Generation of Complete Genomes of Urinary Bacteria using Short- and Long-read Sequencing Technologies
Published on: August 20, 2021
Related Concept Videos
RNA-seq
Before the discovery of RNA-seq, microarray-based methods and Sanger sequencing were used for transcriptome analysis. However, while...
Genome Annotation and Assembly
Sanger Sequencing