Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Acetylcholine biosensor based on the electrochemical functionalization of graphene field-effect transistors
Gonzalo E Fenoy1, Waldemar A Marmisollé2, Omar Azzaroni3
1Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas (INIFTA), Departamento de Química, Facultad de Ciencias Exactas, Universidad Nacional de La Plata (UNLP), CONICET. Diagonal 113 and 64, La Plata, 1900, Argentina; Instituto de Investigación e Ingeniería Ambiental, Universidad Nacional de San Martín, 25 de Mayo y Francia, 1 Piso, 1650, Buenos Aires, Argentina.
Abstract:
We present a new strategy of Acetylcholinesterease (AchE) immobilization on graphene field-effect transistors (gFETs) for building up Acetylcholine sensors. This method is based on the electrosynthesis of an amino moiety-bearing polymer layer on the graphene channel. The film of the copolymer poly(3-amino-benzylamine-co-aniline) (PABA) does not only provide the suitable electrostatic charge and non-denaturing environment for enzyme immobilization, but it also improves the pH sensitivity of the gFETs (from 40.8 to 56.3 μA/pH unit), probably due to its wider effective pKa distribution. The local pH changes caused by the enzyme-catalyzed hydrolysis produce a shift in the Dirac point of the gFETs to more negative values, which are evidenced as differences in the gFET conductivity and thereby constituted the signal transduction mechanism of the modified transistors. In this way, the constructed biosensors showed a LOD of 2.3 μM and were able to monitor Ach in the range from 5 to 1000 μM in a flow configuration. Moreover, they showed a sensitivity of -26.6 ± 0.7 μA/Ach decade and also exhibited a very low RSD of 2.6%, revealing good device-to-device reproducibility. The biosensors revealed an excellent selectivity to interferences known to be present in the extracellular milieu, and the response to Ach was recovered by 97.5% after the whole set of interferences injected. Finally, the biosensors showed a fast response time, with an average value of 130 s and a good long-term response.
More Related Videos
09:39Exploring Biomolecular Interaction Between the Molecular Chaperone Hsp90 and Its Client Protein Kinase Cdc37 using Field-Effect Biosensing Technology
Published on: March 31, 2022
10:45Fabrication of a Solution-gated Indium-Tin-Oxide-based One-piece Transistor Enabling Sensitive Biosensing
Published on: August 29, 2025