Related Experiment Video
Updated: Jan 4, 2026

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
The use of thermal imaging in evaluating musculoskeletal disorders in dentists
Mioara-Raluca Cosoroaba1, Liviu Cirin1, Mirella Dorina Anghel1
1"Victor Babeş" University of Medicine and Pharmacy Timişoara, Romania.
Abstract:
Musculoskeletal disorders (MSDs) caused by incorrect working positions among dentists is a serious health issue and one that leads to decreased productivity and quality of life. Muscle activity and strain is correlated with higher surface temperatures due to increased metabolic activity [2]. The main objective of this study is to evaluate, using thermal imaging, the muscular strain experienced by oral healthcare professionals during work depending on their position, and to assess whether periodic stretching exercises have an impact on preventing MSDs. The study included four subjects and used thermal imaging to evaluate the heat pattern produced by muscle strain in two different states, one while working in incorrect postures and the other after performing stretching exercises. We used a FLIRB200 thermal imaging camera to measure skin surface temperature changes of the underlining muscles in the cervical, right arm triceps, and lumbar areas. According to the imaging, all four subjects recorded a drop in temperature in evaluated muscle regions after performing stretching exercises, corresponding to a decrease in muscle strain. Thermal imaging can be effectively used to evaluate muscle strain and MSDs. Stretching exercises could be viewed as effective preventive measures to avoid MSDs caused by erroneous work postures, however, more subjects are required to draw a definite conclusion.
More Related Videos
06:08Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
X-ray Imaging
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Ultrasonography